Installation
Linux (Red Hat/CentOS/Oracle Linux)
# Download
wget https://docs.broadcom.com/docs-and-downloads/007.2705.0000.0000_storcli_rel.zip
# Descompactar release
unzip 007.2705.0000.0000_storcli_rel.zip
cd storcli_rel
unzip Unified_storcli_all_os.zip
cd Unified_storcli_all_os/Linux
# Instalar RPM
rpm -Uvh storcli-007.2705.0000.0000-1.noarch.rpm
# Verificar instalação
/opt/MegaRAID/storcli/storcli64 -v
# Criar alias para facilitar
alias storcli64='/opt/MegaRAID/storcli/storcli64'
# Adicionar ao .bashrc para persistir
echo "alias storcli64='/opt/MegaRAID/storcli/storcli64'" >> ~/.bashrc
Debian/Ubuntu
cd Unified_storcli_all_os/Ubuntu
dpkg -i storcli_007.2705.0000.0000_all.deb
Windows
cd Unified_storcli_all_os\Windows
storcli64.exe /help
Basic Syntax
General pattern:
storcli64 /c{controller} [/e{enclosure} [/s{slot}]] {command} {parameters}
Components:
Component Description Example /c{n} Controller (0 = first) /c0 /e{n} Enclosure ID /e252 /s{n} Disk slot in enclosure /s0 /v{n} Virtual Drive (array) /v0 all All items /c0/e252/s all json JSON output /c0 show json
Syntax examples:
storcli64 /c0 show # Info do controlador 0
storcli64 /c0/v0 show # Info do VD (virtual drive) 0
storcli64 /c0/e252/s0 show # Info do disco no slot 0
storcli64 /c0/e252/s all show # Todos os discos no enclosure 252
storcli64 /c0/v all show # Todos os arrays
Controller Commands
General Information
# Info completa do controlador
storcli64 /c0 show
# Info resumida
storcli64 /c0 show summary
# Status detalhado
storcli64 /c0 show all
# Versão firmware e status
storcli64 /c0/bbu show
# Saída em JSON (melhor para parsing)
storcli64 /c0 show json
Controller Settings
# Ver políticas ativas
storcli64 /c0 show ctrlproperty
# Definir rebuild rate (10-100%)
storcli64 /c0 set ctrlproperty rebuildrate=30
# Definir taxa de background init
storcli64 /c0 set ctrlproperty bgirate=30
# Cache flush interval (segundos)
storcli64 /c0 set ctrlproperty cacheflushinterval=4
# Modo de cache (WB = WriteBack, WT = WriteThrough)
storcli64 /c0 set ctrlproperty readpolicy=RA writepolicy=WB
BBU (Battery Backup Unit)
# Status da bateria
storcli64 /c0/bbu show
# Info detalhada
storcli64 /c0/bbu show all
# Ciclo de aprendizado (Learn Cycle)
storcli64 /c0/bbu start learn
# Ver tempo remanescente
storcli64 /c0/bbu show preservecache
Virtual Drives (RAID Arrays)
List all arrays
# Listar VDs
storcli64 /c0/v all show
# Detalhado
storcli64 /c0/v all show all
# Em JSON
storcli64 /c0/v all show json
# Resumido
storcli64 /c0/v all show summary
Specific array info
# VD 0
storcli64 /c0/v0 show
# Info completa
storcli64 /c0/v0 show all
# Propriedades de cache
storcli64 /c0/v0 show cachecade
# Performance metrics
storcli64 /c0/v0 show performance
Create Virtual Drive (RAID Array)
# RAID0 com 3 discos
storcli64 /c0/v add type=raid0 drives=252:0,252:1,252:2
# RAID1 (mirror) - 2 discos
storcli64 /c0/v add type=raid1 drives=252:0,252:1
# RAID5 - 4 discos
storcli64 /c0/v add type=raid5 drives=252:0,252:1,252:2,252:3
# RAID6 - 5 discos (com 2 de paridade)
storcli64 /c0/v add type=raid6 drives=252:0,252:1,252:2,252:3,252:4
# RAID10 - 6 discos (3 pares espelhados)
storcli64 /c0/v add type=raid10 drives=252:0,252:1,252:2,252:3,252:4,252:5
# Com nome customizado
storcli64 /c0/v add type=raid5 drives=252:0,252:1,252:2,252:3 name=DataArray
# Com stripe size (default 256KB)
storcli64 /c0/v add type=raid5 drives=252:0,252:1,252:2,252:3 stripesize=64
Delete Virtual Drive
# Deletar VD 0 (requer confirmação)
storcli64 /c0/v0 del
# Forçar delete sem confirmação
storcli64 /c0/v0 del force
Modify array properties
# Cache WriteBack/WriteThrough
storcli64 /c0/v0 set iopolicy=cached # WriteBack
storcli64 /c0/v0 set iopolicy=direct # WriteThrough
# Read Ahead
storcli64 /c0/v0 set rdpolicy=ra # Read Ahead
storcli64 /c0/v0 set rdpolicy=nora # No Read Ahead
# Disk Cache Policy
storcli64 /c0/v0 set pdcache=enable # Cache do disco
storcli64 /c0/v0 set pdcache=disable # Sem cache do disco
# Access Policy
storcli64 /c0/v0 set accesspolicy=rw # Read-Write
storcli64 /c0/v0 set accesspolicy=ro # Read-Only
Array operations
# Iniciar verificação de consistência
storcli64 /c0/v0 start cc
# Parar verificação
storcli64 /c0/v0 stop cc
# Ver progresso de rebuild/CC
storcli64 /c0/v0 show progress
# Pausar operação em background
storcli64 /c0/v0 pause cc
# Resumir operação
storcli64 /c0/v0 resume cc
Physical Drives (Disks)
List all disks
# Lista resumida
storcli64 /c0/e252/s all show
# Detalhado
storcli64 /c0/e252/s all show all
# Em JSON
storcli64 /c0/e252/s all show json
# Por status
storcli64 /c0/e252/s all show|grep -i online
Specific disk info
# Disco no slot 0
storcli64 /c0/e252/s0 show
# Detalhado
storcli64 /c0/e252/s0 show all
# Estatísticas SMART
storcli64 /c0/e252/s0 show smartdump
Disk states
State Description Onln Online - working normally Offln Offline - failure detected DHS Dedicated Hot Spare - dedicated spare GHS Global Hot Spare - global spare UGood Unconfigured Good - new/unconfigured disk UBad Unconfigured Bad - failed disk Rbld Rebuild - rebuilding Copyback CopyBack - copying back to new disk
Disk operations
# Forçar online um disco
storcli64 /c0/e252/s0 set online
# Forçar offline (cuidado!)
storcli64 /c0/e252/s0 set offline
# Iniciar rebuild forçado
storcli64 /c0/e252/s0 start rebuild
# Parar rebuild
storcli64 /c0/e252/s0 stop rebuild
# Localizar disco (LED acende)
storcli64 /c0/e252/s0 start locate
# Parar localização
storcli64 /c0/e252/s0 stop locate
# Forçar como bom (emergência)
storcli64 /c0/e252/s0 set good force
# Limpar erro SMART
storcli64 /c0/e252/s0 clear smarterror
Firmware & Properties
# Ver firmware do disco
storcli64 /c0/e252/s0 show all | grep -i firmware
# Atualizar firmware (arquivo .fw)
storcli64 /c0/e252/s0 download fwfile=disk_fw.fw
# Ver media type (HDD, SSD, NVMe)
storcli64 /c0/e252/s all show | grep -i "Med\|Model"
# Temperatura do disco
storcli64 /c0/e252/s0 show all | grep -i temp
Hot Spares
List Hot Spares
# Ver todos os hot spares
storcli64 /c0/e252/s all show | grep -i "dhs\|ghs"
# Detalhado
storcli64 /c0/e252/s all show all | grep -B2 -A2 "DHS\|GHS"
Create Dedicated Hot Spare (DHS)
# Designar disco como DHS para grupo 0
storcli64 /c0/e252/s6 set hotsparedrive dedicated dg=0
# Remover DHS
storcli64 /c0/e252/s6 set hotsparedrive delete
Create Global Hot Spare (GHS)
# Designar disco como GHS (cobre todos os arrays)
storcli64 /c0/e252/s6 set hotsparedrive global
# Remover GHS
storcli64 /c0/e252/s6 set hotsparedrive delete
Hot Spare Properties
# Rebuild automático ativado
storcli64 /c0 set ctrlproperty autorebuild=on
# Desativar rebuild automático
storcli64 /c0 set ctrlproperty autorebuild=off
# Restaurar hot spare após inserção de disco novo
storcli64 /c0 set ctrlproperty restoredriveoninsert=on
Enclosures
List enclosures
# Resumido
storcli64 /c0/e all show
# Detalhado
storcli64 /c0/e all show all
# Info específica
storcli64 /c0/e252 show
# Discos no enclosure 252
storcli64 /c0/e252/s all show
Detailed enclosure info
# Todos os sensores
storcli64 /c0/e252 show all
# Fabricante e modelo
storcli64 /c0/e252 show | grep -i "vendor\|product"
# Temperatura (se há sensores)
storcli64 /c0/e252 show | grep -i temp
# Status de power supplies
storcli64 /c0/e252 show | grep -i "power"
Monitoring & Health
General system status
# Dashboard completo
storcli64 /c0 show
# Health check
storcli64 /c0 show health
# Alertas ativos
storcli64 /c0 show alerts
# Eventos do log
storcli64 /c0 show events
# Log de eventos (últimos 100)
storcli64 /c0 show events |tail -100
Monitor rebuilds and operations
# Progresso de rebuild
storcli64 /c0/v all show progress
# Progresso detalhado
storcli64 /c0/v all show progress detail
# Progresso de Consistency Check
storcli64 /c0/v0 show cc progress
# Progresso de Patrol Read
storcli64 /c0 show patrolprogress
Performance metrics
# Performance do array
storcli64 /c0/v0 show performance
# IOPS, latência, throughput
storcli64 /c0 show performance
# Cache hit rate
storcli64 /c0 show cachestats
Scheduled tasks
# Ver tarefas agendadas
storcli64 /c0 show ctrlproperty | grep -i "patrol\|cc"
# Consistency Check
storcli64 /c0 show consistencycheckprogress
# Patrol Read status
storcli64 /c0 show patrolprogress
# Iniciar Patrol Read manualmente
storcli64 /c0 start patrolread
# Parar Patrol Read
storcli64 /c0 stop patrolread
Troubleshooting
Failed disk
# Scenario: Disco 252:0 falhou
# 1. Verificar status
storcli64 /c0/e252/s0 show
# 2. Ver array que usa o disco
storcli64 /c0/v all show | grep "252:0"
# 3. Se há hot spare, rebuild começa automaticamente
storcli64 /c0/v0 show progress
# 4. Se sem hot spare, criar VD temporário com outro disco
# e depois re-agregar o disco novo quando chegar
# 5. Disco novo chegou: trocar disco falho
# Localize com LED
storcli64 /c0/e252/s0 start locate
# 6. Após trocar, disco é reconhecido automaticamente
storcli64 /c0/e252/s all show
# 7. Se era DHS, automaticamente volta para DHS
# Se era array, inicia rebuild automático
Degraded array
# Detectar degradação
storcli64 /c0/v all show | grep -i "dgrd\|pdgd"
# Ver qual disco faltou
storcli64 /c0/v0 show all
# Reconstruir manualmente se necessário
storcli64 /c0/e252/s0 start rebuild
# Monitorar progresso
storcli64 /c0/v0 show progress
Disk not showing up
# Verificar física (LED localized)
storcli64 /c0/e252/s0 show
# Se estado é UGood (Unconfigured Good)
# 1. Checar se precisa ser inicializado
storcli64 /c0/e252/s all show | grep -i "ugood"
# 2. Setar como hotspare
storcli64 /c0/e252/s0 set hotsparedrive dedicated dg=0
# 3. Forçar online se offline
storcli64 /c0/e252/s0 set online
Rebuild error
# Ver erro
storcli64 /c0/v0 show progress
# Se travado, parar e reiniciar
storcli64 /c0/e252/s0 stop rebuild
storcli64 /c0/e252/s0 start rebuild
# Ver log de erros
storcli64 /c0 show events | grep -i "rebuild\|error"
# Se problema persistir, forçar disco bom
storcli64 /c0/e252/s0 set good force
Cache not working
# Verificar se BBU está ok
storcli64 /c0/bbu show
# Se BBU falhar, cache muda para WriteThrough
storcli64 /c0/v0 show | grep -i "cache"
# Verificar política de cache
storcli64 /c0/v0 show cachecade
# Re-habilitar cache após BBU repair
storcli64 /c0/v0 set iopolicy=cached
Slow performance
# Check rebuild/CC em execução
storcli64 /c0/v all show progress
# Reduzir taxa de rebuild se muito lento
storcli64 /c0 set ctrlproperty rebuildrate=20
# Aumentar se há I/O livre
storcli64 /c0 set ctrlproperty rebuildrate=60
# Ver cache statistics
storcli64 /c0 show cachestats
# Ver temperatura (throttling?)
storcli64 /c0 show all | grep -i "temp"
Real Use Cases
Scenario 1: Replace failed disk with hot spare
# Problema: Disco 252:0 falhou em RAID10
# Step 1: Verificar status
storcli64 /c0/v all show
# Output: VD 0/239 RAID10 Dgrd (degradado)
storcli64 /c0/e252/s all show
# Output: 252:0 Offln (falhou)
# 252:6 DHS (hot spare disponível)
# Step 2: Hot spare ativa automaticamente, inicia rebuild
storcli64 /c0/v0 show progress
# Rebuild em progresso: 45%
# Step 3: Monitorar até 100%
# (pode levar horas em discos grandes)
# Step 4: Disco novo chegou
# Trocar disco físico no slot 252:0
# Step 5: Verificar se foi reconhecido
storcli64 /c0/e252/s0 show
# Output: UGood (novo disco não configurado)
# Step 6: Disco volta como DHS automaticamente
storcli64 /c0/e252/s all show
# 252:0 agora DHS novamente
Scenario 2: Expand RAID by adding disk
# Problema: RAID5 com 4 discos, quer adicionar 5º
# Cuidado: StorCLI atual não suporta expand direto
# Solução: Delete VD e recrie com todos os discos
# Step 1: Fazer backup
# ... (backup externo necessário)
# Step 2: Delete VD
storcli64 /c0/v0 del force
# Step 3: Verificar discos
storcli64 /c0/e252/s all show
# 252:0 a 252:4 devem estar UGood
# Step 4: Criar novo RAID5 com 5 discos
storcli64 /c0/v add type=raid5 drives=252:0,252:1,252:2,252:3,252:4
# Step 5: Initialize VD
storcli64 /c0/v0 start init full
Scenario 3: Convert RAID0 to RAID1 (mirror)
# Problema: RAID0 com 2 discos, quer redundância
# Step 1: Backup obrigatório (RAID0 = sem redundância)
# ... (cópia para storage externo)
# Step 2: Delete RAID0
storcli64 /c0/v0 del force
# Step 3: Criar RAID1
storcli64 /c0/v add type=raid1 drives=252:0,252:1
# Step 4: Initialize
storcli64 /c0/v0 start init full
# Step 5: Monitorar
storcli64 /c0/v0 show progress
Scenario 4: Proactive monitoring
# Cron job: verificar saúde a cada hora
#!/bin/bash
CONTROLLER=0
STORCLI="/opt/MegaRAID/storcli/storcli64"
# Verificar estado dos arrays
$STORCLI /c$CONTROLLER/v all show | \
grep -E "Optl|Dgrd|Offln|Rbld" | \
mail -s "RAID Status Alert" [email protected]
# Verificar temperatura
TEMP=$($STORCLI /c$CONTROLLER show all | grep "Ctrl temperature" | awk '{print $NF}')
if [ ${TEMP%C} -gt 60 ]; then
echo "Controller hot: $TEMP" | mail -s "Temperature Alert" [email protected]
fi
# Verificar BBU
$STORCLI /c$CONTROLLER/bbu show | grep -i "optimal" || \
echo "BBU problem detected" | mail -s "BBU Alert" [email protected]
Scenario 5: Disk migration (pure rebuild)
# Problema: Trocar todos os 6 discos de RAID5 por discos novos
# Step 1: Backup crítico (VD será deletado)
# ... (cópia completa para storage externo)
# Step 2: Delete VD
storcli64 /c0/v0 del force
# Step 3: Todos os 6 discos antigos ficam UGood
storcli64 /c0/e252/s all show
# Step 4: Trocar discos físicos 1 a 1 (eles saem UGood, novos entram UGood)
# Step 5: Criar novo RAID5 com discos novos
storcli64 /c0/v add type=raid5 drives=252:0,252:1,252:2,252:3,252:4
# Step 6: Restaurar dados do backup
Tips & Best Practices
✅ Recommendations
-
Always backup before destructive operations (delete VD, init)
-
Monitor temperature — rebuild/init generates heat
-
BBU is essential — without battery, cache is WriteThrough (slow)
-
Dedicated hot spare — faster than global
-
RAID6 or RAID10 — for critical data
-
Patrol Read enabled — detects errors before failure
-
Periodic logs — track degradation
-
Updated firmware — bug/performance fixes
❌ Caution
-
del forcedeletes data immediately -
set good forcecan corrupt data -
Slow rebuild on large disks — let it run
-
Multiple simultaneous rebuilds degrade I/O
-
WriteBack cache without BBU = risk of data loss
-
Do not change controller/enclosure without planning
Quick Reference
Task Command Check status storcli64 /c0 show Check arrays storcli64 /c0/v all show Check disks storcli64 /c0/e252/s all show Create RAID5 storcli64 /c0/v add type=raid5 drives=252:0,252:1,252:2,252:3 Create RAID1 storcli64 /c0/v add type=raid1 drives=252:0,252:1 Hot spare storcli64 /c0/e252/s6 set hotsparedrive dedicated dg=0 Rebuild storcli64 /c0/e252/s0 start rebuild Progress storcli64 /c0/v0 show progress Locate storcli64 /c0/e252/s0 start locate BBU status storcli64 /c0/bbu show Cache mode storcli64 /c0/v0 set iopolicy=cached Performance storcli64 /c0 show performance Events storcli64 /c0 show events
Version & Info
-
StorCLI Version: 007.2705.0000.0000 (26.07)
-
Controller: Broadcom MegaRAID
-
Compatible with: Dell PowerEdge R620/R630/R720/R730/R760/R760xs
📚 Official References
Downloads (Broadcom)
-
StorCLI Release Bundle: https://docs.broadcom.com/docs-and-downloads/007.2705.0000.0000\\\_storcli\\\_rel.zip
-
Official Documentation: https://docs.broadcom.com/docs/1232743397
Related Documentation
-
Broadcom MegaRAID Docs: https://docs.broadcom.com
-
Dell PowerEdge Manuals: https://www.dell.com/support/manuals/
-
Oracle Linux RAID Tuning: https://docs.oracle.com/
Alternatives & Related Tools
-
MegaCLI (legacy) — old version, use StorCLI instead
-
storcli64 — CLI tool (This guide)
-
StorCLI Snapdump — advanced logging
-
Dell Integrated Dell Remote Access Controller (iDRAC) — via web UI
Disclaimer
This guide is provided as-is, without warranties. Always back up before destructive operations. StorCLI and MegaRAID are registered trademarks of Broadcom Inc. For official support, open a ticket with Broadcom or your vendor.
Keep reading
Read also
TutoriaisBusiness Services in Nyverra Portal: Translating IT into Business
The business doesn't feel a server go down — it feels email stop. The Business Services (Service Mapping) module of Nyverra ITSM Portal connects services like Email, ERP or PACS to CMDB assets, revealing the real impact of each failure.
5 min de leitura
SegurançaRPO vs RTO: How to Define Before Buying Backup (and Why Most Companies Get It Wrong)
Most companies buy backup asking the wrong question: "how much does it cost?". The right question is: how much data can I lose (RPO) and how long can I be down (RTO). Discover how to define these numbers per system and avoid purchasing protection based on price, not on real need.
9 min de leitura
TutoriaisRoles and Permissions in Nyverra Portal: Tailored Access Control
RBAC is the foundation of access control. See how the Roles module in Nyverra Portal ITSM defines granular profiles and permissions, protects sensitive functions with 2FA, enables temporary delegation by period, and relies on the principle of least privilege.
5 min de leitura
Comments
No comments yet
Be the first to share your thoughts on this article.

Leave a comment